Concept

Tear strength — where it appears

How much force a fabric resists once a tear has started, which is decided at the crack tip rather than by the cloth's tensile strength. Fewer interlacings let threads group and share the load, which is why a loose weave often tears better than a firm one.

Named by 6 essays across 4 fields — each of them below, with the objects they name alongside it.

Where the floats are in the 5-end satin. Every longest run of warp on the face, marked. A float is smooth because nothing interrupts it, which is the same reason it snags: there is a length of thread lying on the surface with nothing holding it down.

The float decides

How far a thread runs on the face before it goes under is one number, and it sits behind lustre, drape, snagging, abrasion, tear strength and how densely the cloth can be set. Almost nothing else in the subject has that reach.

weaves · Float
What the geometry says about a tear. A slit in a woven cloth, with the ends ahead of the tip gathered into the group that will break together. How many can gather is the opening divided by the slack in each gap, and the slack is the thread spacing less the thread diameter — an expression with no weave in it at all.

Does a loose weave tear better

The trade says a twill tears stronger than a plain weave of the same yarn, because fewer interlacings let the threads group. The geometry of that grouping has no weave in it at all — and where the geometry does speak, it predicts the opposite.

weaves · Float
What a raising machine can catch in a 3/1 twill. The draft with every weft float long enough for a raising wire to lift marked on it. The teeth need an unsupported length of thread on the surface, so a cloth in which every thread is bound at every crossing offers them nothing at all — which is why a napped fabric is always a twill or a satin and never a plain weave.

Raising spends the cloth's strength

Fibre standing up on the surface is fibre no longer in the load path. A nap is warmth bought with tensile strength, and the exchange rate runs along the same axis as everything else the float decides — which means a fabric cannot be optimised for both ends of it.

finishing · Nap
A tear breaks threads or pulls them out. The grip a cloth has on a thread at the tip of a tear, against the sett, with the thread's own strength drawn across. Below the line the thread slides and the yarns group, which is the trade's explanation of why a loose weave tears well; above it the thread breaks where it is and grouping never happens. The essay that asked it could not compute this: it needed a friction, and the fancy weaves supplied one.

A tear stops where the grip is

This collection asked whether a loose weave tears better and had to answer that the geometry could not say — it supplies a grip count and a slack, and neither is a force. The fancy weaves brought a friction. With it the question has an answer — a cloth's threads slide up to a computable sett and break above it — and a ripstop grid has a bound with no free parameter in it.

applied · Damage
What a tear asks for is the weakest of a few. A tensile test pulls every thread in the width and averages them. A tear pulls the handful in the triangle at the tip of the cut, and what lets it move is whichever of those is weakest — so the quantity that governs is the minimum of a small sample, and two things follow that no mean can show. Its expectation is below the mean: at CV 15% the weakest of 4 is 0.853 of the mean thread, and the weakest of 40 is 0.718. And its scatter is enormous compared with a tensile test's: 10.9% against the 0.75% a mean of four hundred threads would show. A tear strength that varies by a tenth between specimens of the same cloth is not a badly run test. It is the only answer an extreme of four can give.

A tear asks fewer threads than a pull

A strip test averages a hundred threads and a tear interrogates four. That difference alone accounts for the two things everybody knows about tear testing — that it reads low, and that it scatters — without anything about the cloth being different between the two tests.

applied · Damage
A bundle is weaker than the threads it is made of. Threads pulled in parallel do not break together. The weakest goes first and hands its load to the rest, which are now carrying more than they were, so the bundle's peak load is reached before every thread is at its own strength. With a load per surviving thread of x carried by the fraction that has not yet broken, the bundle's strength per thread is the largest value of x(1 − F(x)) — Daniels' maximum, which for a lognormal at CV 15% is 0.7380 of the mean thread, reached with 93% of the threads still unbroken. A simulated bundle that knows none of that arithmetic sits above the limit at every finite size — its strength is a maximum over the sample it happens to have drawn — and closes on it as the bundle grows: 0.753, 0.744, 0.741 at the last three sizes. The scatter falls the other way, from 14.5% at one thread to 0.7% at 1600.

A bundle is weaker than its threads

Threads pulled together do not break together. The weakest goes first and hands its load to the rest, so a bundle carries its maximum well before every thread is at its own limit — and the shortfall is a quarter, decided by the spread and by nothing else.

mechanics · Tensile

Named alongside it

The objects these essays reach for when they reach for this one.

FloatFrictionAbrasionCoefficient of variationOrder statisticPopulationPropagationSpecificationAreal densityBreaking extensionBundle strengthCapstan

All concepts